Process current clamp meter mA

Item No. FLUKE 771
In stock: 1
CHF 1,017.00

All prices exclude VAT.

mA process current clamp
The Fluke 771, 772 and 773 offer:
-Highest accuracy in its class: 0.2 %
-Resolution and sensitivity of 0.01 mA
-Measurement of 4 to 20 mA signals without interrupting the

Calibration certificate

Calibration is performed in our own laboratory before shipping.

Number
  • Official Fluke Service Center
  • ISO 17025 accredited calibration laboratory
  • 2-year warranty on all new devices
  • Delivery in 3-5 working days

Fluke 771, 772 and 773 offer

  • Highest accuracy in its class: 0.2 %
  • Resolution and sensitivity of 0.01 mA
  • Measurement of 4 to 20 mA signals without interrupting the loop
  • Measurement of mA signals for analog inputs/outputs on PLCs and control systems
  • Dual backlit display with mA indicator
  • Measured value and percentage value of the 4 to 20 mA measuring range
  • Measuring point lighting illuminates hard-to-see wires in dark control cabinets
  • Detachable pliers with extension cable for measurements in tight spaces

Place

  • Measurement of 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatic switching of the 4 to 20 mA output for testing over longer distances
  • Energy-saving function, automatic shut-off; timed shut-off of the backlight extends battery life
  • life
  • Hold function detects and displays fluctuating measurements. Additionally, models 772 and 773:
  • Measuring signals between 4 and 20 mA with a measurement in the circuit
  • Simultaneous measurement of mA values in a 24-V circuit
  • Loop current for power supply and testing of sensors
  • Providing signals between 4 and 20 mA for the inputs/outputs and current-pressure transducers of test control systems
  • Linear ramp of the mA output or 25 %

Stair exit signal

  • Automatic switching of the 4 to 20 mA output for testing over longer distances

Exclusive features of the Model 773

  • Measurement of DC voltage for testing the 24V
  • Power supply or input/output signals of the voltage
  • Supplying DC voltage for testing input devices that tolerate 1 to 5 V or 0 to 10 V signals
  • A scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA measured by the mA current clamp.
  • Signal corresponds
  • Enables logging of the mA signal to a separate logger without interrupting the loop.
  • The mA output signal enables a digital logging multimeter

or another device recording a 4 to 20 mA

  • Signals without interrupting the loop
  • mA input/output: Simultaneous measurement of the mA signal with the current clamp and output of a mA signal
  • Apply a mA input signal to a device and measure the 4 to 20 mA output at the devices, such as valves or mA isolators.
  • Linear ramp of the voltage output or 25 % staircase output signal
  • Automatic voltage output adjustment for long-distance testing

Request our expertise

We offer individual consultations – whether on site, by telephone or via video call.

To the form